==STATUS== As of Nov 16, 2013

  • NH138 Unit #2 installed sensor and comm head 11/15. Audio indicates viable nest but turtles are lethargic
  • NH144 Unit #3 installed comm head 11/15. No sounds. May not be a viable nest.

Unit #1 will stay in the lab for testing since there are probably no more viable nests to monitor this season.


==STATUS== As of Nov 12, 2013

  • NH134 8/12/13 Sensor, no Comm Tower, Excavated 11/12/13 (113 unhatched eggs and one live hatchling, hatched but didn't emerge from the nest)
  • NH137 8/12/13 Unit #3 x3448 (hardware=V3 software=V17), Excavated 11/12/13 (165 eggs in the nest 158 were undeveloped)
  • NH144 8/21/13 Unit #2 x1348 (hardware=V2 software=V13), actively monitoring nest
  • NH145 8/30/13 Sensor, no Comm Head

Straight Talk Phone Service

  • xxx6310 Unit #1 012482003785595 Service End Date: 11/29/13
  • xxx1348 Unit #2 012482000108114 Service End Date: 11/24/13
  • xxx3448 Unit #3 012482000739223 Service End Date: 11/29/13
  • 012482003785595 Inactive Phone, used for testing and debugging

DEBUGGING

  • Oct 30. Unit #3 goes dark after ~ 10 transmissions, then resets ~ one day later. Called phone; 5 rings "I'm sorry the person you have called has a voice mail box not set up yet, goodbye"
  • Oct 21. Called Strait Talk phone support re; Unit #2 phone; Message says “need to program some codes into my Straight Talk phone”

Sensor fill material

  • NH134 - silicone
  • NH137 - epoxy
  • NH144 - epoxy
  • NH145 - silicone

LOCATION OF NESTS